Latches & Switches

These products meet your demands to reduce power budget and space utilization, while also taking care of
functional safety and system flexibility aspects.
Applications




Latch and Switch - 2 wire sensors | |||||||||||||||
Part No. | Typical Bop/Brp | TC | Ioff | Supply Voltage | Output Type | Package & pople active | Magnetic polarity | ICAP | IOS26262 | AXIS | |||||
mT | ppm/°C | mA | V | TSOT | UA | ||||||||||
Latch | 0,8/ -0,8 - 11,8/ -11,8 | -2000-0 | 3,3/6 | 2,7 - 24 | current source | ● | ● | Direct | ● | ● | Bx | ||||
-10/ 10 | 0 | 3,3/6 | 3,8 - 16 | Voltage controlled current source | ● | Direct | ● | ● | |||||||
Switch | -3,8/ -3,8 - 20/ 18 | -2000-0 | 3,3/6 | 2,7 - 24 | current source | ● | ● | Direct/ Inverted | ● | ● | |||||
Latch and Switch - Dual hall sensors | |||||||||||||||
Part No. | Typical Bop/Brp | TC | Idd | Supply Voltage | Output Type | Package & pole active | Axis | ||||||||
mT | ppm/°C | mA | V | TSOT | VA | ||||||||||
Latch | 2,5/ -2,5 | 0 | 7,5 | 4,5 - 16 | Speed&Speed | ● | 2x Bz | ||||||||
2,5/ -2,5 -7,5/ -7,5 | -1100/ 0 | 4,5 | 2,7 - 24 | Speed&Direction | ● | 2x Bz | |||||||||
3/ -3 | -1800 | 5 | 3,8 - 24 | Speed& Speed + fd | ● | 2x Bz | |||||||||
Latch and Switch - 3 wire sensors | |||||||||||||||
Part No. | Typical Bop/Brp | TC | Idd | Supply Voltage | Output Type | Package & pole active | Magnetic polarity | Axis | |||||||
mT | ppm/°C | mA | V | TSOT | UA | ||||||||||
Switch | -13,5/ -8,5 - 66/ 50 | -2000 - 0 | 3 | 2,7 - 24 | Open Drain | ● | ● | Direct/ Inverted | Bx | ||||||
12 /10,5 | 0 | 2,2 | 2,5 - 5,5 | Open Drain | ● | Direct | |||||||||
Latch | -0,5/ 0,5 - 14,9/ -14,9 | -2000 - 0 | 3 | 2,7 - 24 | Open Drain | ● | ● | Bx | |||||||
2/ -2 | 0 | 2,2 | 2,5 -5,5 | Open Drain | ● | ||||||||||
2/ -2 | 0 | 2,2 | 2,5 -5,5 | Open Drain | ● | ||||||||||
Latch and Switch - General purpose sensors | |||||||||||||||
Part No. | Typical Bop/Brp | TC | Idd | Supply Voltage | Output Type | Package & pole active | |||||||||
mT | ppm/°C | mA | V | TSOT | UA | ||||||||||
Latch | 5/ -5 | 0 | 3 | 3,5 - 24 | Open Drain | ● | ● | ||||||||
14/ -14 | 0 | 3 | 3,5 - 24 | Open Drain | ● | ||||||||||
3/ -3 | 0 | 3 | 3,5 - 24 | Open Drain | ● | ● | |||||||||
3/ -3 | 0 | 3 | 3,5 - 24 | Open Drain | ● | ||||||||||
3/ -3 | 0 | 3 | 3,5 - 24 | Open Drain | ● | ● | |||||||||
5/ -5 | 0 | 3 | 2,2 - 18 | Open Drain | ● | ● | |||||||||
3/ -3 | 0 | 3 | 2,2 - 18 | Open Drain | ● | ● | |||||||||
3/ -3 | -2000/ -1100 | 3 | 2,7 - 24 | Open Drain | ● | ||||||||||
Switch | 5,5/ 3,5 | 0 | 3 | 3,5 - 24 | Open Drain | ● | |||||||||
5,5/ 3,5 | 0 | 3 | 3,5 - 24 | Open Drain | ● | ||||||||||
5,5/ 3,5 | 0 | 3 | 3,5 - 24 | Open Drain | ● | ||||||||||
12/ 7,5 | 0 | 3 | 3,5 - 24 | Open Drain | ● | ● | |||||||||
12/ 7,5 | 0 | 3 | 3,5 - 24 | Open Drain | ● | ||||||||||
25/ 20 | 0 | 3 | 3,5 - 24 | Open Drain | ● | ● | |||||||||
Latch and Switch - μPower Sensors | |||||||||||||||
Part No. | Typical Bop/Brp | TC | Idd | Supply Voltage | Output Type | Package & pole active | |||||||||
mT | ppm/°C | mA | V | TSOT | UA | UTQFN | VA | ||||||||
Latch | 2/ -2 | 0 | 36 μA | 1,6 - 3,6 | Push Pull | ● | |||||||||
Omnipolar Switch | 3,5/ 2,5 | 0 | 3 μA | 1,6 - 3,6 | Open Drain | ● | ● | ||||||||
Latch and Switch - Customer programmable sensor | |||||||||||||||
Part No. | Typical Bop/Brp | TC | Ioff | Supply Voltage | Output Type | Package & pople active | ICAP | IOS26262 | AXIS | ||||||
mT | ppm/°C | mA | V | TSOT | UA | ||||||||||
2-Wire | -40...40 / -100...100 | 0-2000 | 3,3/ 6 | 2,7 - 24 | Current source | ● | ● | ● | A | Bx | |||||
3-Wire | -40..40 / -80..80 | 0-2000 | 3 | 2,7- 24 | Open Drain | ● | ● | Bx | |||||||
-40..40 / -90..90 | 0-2200 | PROGR | 3,3 - 18 | Open Drain | ● | ● | B | Bx | |||||||
Dual Die | -80..80 | 0 | 3 | 2,7 - 24 | Open Drain | VA | 2x Bz | ||||||||
-90...90 | 0-2200 | PROGR | 3,3 - 18 | Open Drain | SOIC8 | B | 2x Bz | ||||||||
Latch and Switch - μPower Sensors for Automotive | |||||||||||||||
Part No. | Typical Bop/Brp | TC | Ioff | Supply Voltage | Output Type | Package & pople active | Magnetic polarity | Options | Axis | ||||||
mT | ppm/°C | mA | V | TSOT | UA | Power & diag mode | Top (ms) | Tick repetition | Tick duration | ISO26262 | |||||
3-wire Switch | -16,85/ -17,85 - 13,5/ 8,5 | -2200 - 0 | 0,007 - 3 | 3,3 - 18 | Open Drain | ● | ● | Direct/ Inverted | uNoDiag/ TickMsg/ OutOnMsg/ FIddMsg | 0,2 - 60 | Top | 128 | B/ A | Bx |